
	<!DOCTYPE ArticleSet PUBLIC "-//NLM//DTD PubMed 2.0//EN" "http://www.ncbi.nlm.nih.gov:80/entrez/query/static/PubMed.dtd">
	<ArticleSet>

	<Article> 

	<Journal> 

	<PublisherName>International Science Community Association</PublisherName>

	<JournalTitle>Research Journal of Chemical Sciences</JournalTitle> 

	<Issn></Issn>

	<Volume>15</Volume>

	<Issue>1</Issue>

	<PubDate PubStatus="ppublish"> 

	<Year>2025</Year> 

	<Month>02</Month> 

	<Day>18</Day> 

	</PubDate>

	</Journal>



	<ArticleTitle>Simple and sensitive LC-ESI-MS method for estimation of sildenafil in plasma samples</ArticleTitle> 


	<FirstPage>1</FirstPage>

	<LastPage>7</LastPage>



	<ELocationID EIdType="pii"></ELocationID>

	<Language>EN</Language> 
	<AuthorList>

	
		<Author> 

		<FirstName>Zaware</FirstName>

		<MiddleName> </MiddleName>

		<LastName>Sandeep </LastName>

		<Suffix>1</Suffix>

		<Affiliation>Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Lahoti</FirstName>

		<MiddleName> </MiddleName>

		<LastName>Neel </LastName>

		<Suffix>2</Suffix>

		<Affiliation>Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India</Affiliation>

		</Author>
		<Author> 

		<FirstName>Shinde </FirstName>

		<MiddleName> </MiddleName>

		<LastName>Hrushikesh </LastName>

		<Suffix>3</Suffix>

		<Affiliation>Synergen Bio Private Limited, Old Mumbai - Pune Highway, Wakadewadi, Shivajinagar, Pune, Maharashtra - 411003, India</Affiliation>

		</Author>

	<Author>

	<CollectiveName></CollectiveName>>

	</Author>

	</AuthorList>


	<PublicationType>Research Paper</PublicationType>


	<History>  
	<PubDate PubStatus="received">
	<Year>2023</Year>
	<Month>9</Month>
	<Day>20</Day>
	</PubDate>
	<PubDate PubStatus="accepted">										
	<Year>2025</Year> 
	<Month>02</Month>									
	<Day>18</Day> 
	</PubDate>

	</History>
	<Abstract>The quantity of sildenafil in human plasma was determined using a simple and incredibly accurate LC-ESI-MS approach. Thermo, Hypurity Cl8, 100*4.6 mm, 5µm, was injected with sildenafil and sildenafil d3 (internal standard), which were extracted from the plasma using the solid phase extraction technique. Acetonitrile: 0.1% Formic Acid (70:30, v/v) made up the mobile phase, which was supplied isocratically at a flow rate of 0.6 mL/min. The run time was 3 minutes, and the MRM mode for sildenafil and internal standard sildenafil d3 was found at m/z 475.2→283.2 and 478.2→283.2. The calibration curve for sildenafil was linear between 25.0 and 2000 ng/mL, and the detection limit was 25.0 ng/mL. A validated LC-MS/MS method was used to determine drug concentrations.</Abstract>

	<CopyrightInformation>Copyright@ International Science Community Association</CopyrightInformation>

	<ObjectList> 
	<Object Type="keyword">
	<Param Name="value"></Param>
	</Object>

	</ObjectList>	

	</Article>

	</ArticleSet>
	