A New Simple Ester Ionophore Based Calcium Ion Selective Electrode − Preparation and its Analytical Application
Author Affiliations
- 1Department of Chemistry, Avinashilingam Institute for Home Science and Higher Education for Women Coimbatore- 641043, Tamilnadu, INDIA
Res. J. Recent Sci., Volume 3, Issue (ISC-2013), Pages 362-365, (2014)
Abstract
A new simple efficient calcium ion selective electrode has been prepared using simple ester. A heterogeneous precipitate has been used as ion carriers for the preparation of Ca (II) selective membrane sensor. The sensor exhibits a near Nernstian response for Ca(II) ion over a concentration range of 1.0 x 10-4M to 1.0x10-1M. The proposed sensors revealed relatively good selectively and high sensitivity for Ca(II)over a mono and divalent cations and anions . It can be used within the pH range of 3.42 to 6.24. The effect of medium and the selectivity coefficient values were evaluated using fixed interference method found to give a better response. It was also successfully used in the analysis of concentration of calcium in various real samples.
References
- Shamsipur M., Soleymanpour A., Akhond M., Sharghi H. and Massah A. R., Uranyl-selective PVC membrane electrodes based on some recently synthesized benzosubstituted macrocyclic diamides, Talanta., 58(2), 237–246 (2002)
- Zhang Z.R. and Yu R.Q., The synthesis and membrane transport characteristics of macrocyclic polyether ligands composed of 1,10-phenanthroline as carriers for primary amine species, Talanta., 41(2), 327–333 (1994)
- Singh A.K., Saxena P., Mehtab S. and Gupta B., Strontium(II)-selective electrode based on a macrocyclic tetraamide, Talanta., 69(2), 521–526 (2006)
- Singh A.K., Saxena P. and Panwar A., Manganese(II)-selective PVC membrane electrode based on a pentaazamacrocyclic manganese complex, Sensors and Actuators B., 110(2), 377–381 (2005)
- Ganjali M.R., Razavi T., Dinarvand R., Riahi S. andNorouzi P., New Diltiazem Potentiometric Membrane Sensor Stands on Theoretical Calculations as a Useful Device for Diltiazen Hydrochloride Analysis in Pharmaceutical Formulation and Urine, Int. J. Electrochem. Sci., 3(12) ,1543–1558 (2008)
- Ganjali M.R., Memari Z., Faridbod F. and Norouzi P., Samarium Biosensor: An Asymetric Potentiometric Membrane Sensor , Int. J. Electrochem. Sci., 3(10), 1169–1179 (2008)
- Beheshti S.S. and Amini M.K., A simple and selective Flow –Injection potentiometric method for determination of iodide based on a Coated Glassy Carbon ElectrodeSensor, Int. J. Electrochem. Sci.,2(10), 778–787 (2007)
- Zhang H., Zhang Z., Li J. and Sh. Cai., Effects of Mg2+ on Supported Bilayer Lipid Membrane on a Glassy Carbon Electrode during Membrane Formation, Int. J. Electrochem. Sci., 2(10), 788–796 (2007)
- Paker P., McGraw-Hill Concise Encyclopaedia of Science and Technology, McGraw-Hill, New York, NY, USA, 1994
- Souza S.F.D., Microbial biosensors, Biosensors and Bioelectronics., 16(6), 337–353 (2001)
- White P.J. and Broadley M.R., Calcium in Plants, Ann.Bot., 92(4), 487-511 (2003)
- Mank M., Reiff D.F., Heim N., Friedrich M.W., Borst A. and Griesbeck O., A FRET- Based Calcium Biosensor with Fast Signal Kinetics and High Fluorescence Change, Biophysical Journal., 90(5), 1790–1796 (2006)
- Lakshminarayanaiah N., Calcium Ion Selective Electrode, J. Membrane Science., 255-271 (1981)
- Ashok Klumar Singh and Sameena Mehtab, Calcium(II)-selective potentiometric sensor based on -furildioxime as neutral carrierSensors and Actuators B., 123(1), 429–436 (2007)
- Erol Akyilmaz and Ozge Kozgus., Determination of calcium in milk and water samples by using catalase enzyme electrode, Food Chemistry., 115, 347–351 (2009)
- Fujita H. Park J. Meissner R. Duclous O. Van Lintel H. and Kenaced P., 19th International conference on miniaturized systems for chemistry and Life Sciences, 3-7 October 2010, The Netherlands, (2010)
- Craggs A., Moody G.J. and Thomas J.D.R., PVC matrix membrane ion-selective electrodes. Construction and laboratory experiments,J.Chem.educ., 51 (8), 541 (1974)